Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (2024)

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (1) Cielo

Updated November 10, 2023

21 mins read

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (2)

Heat pumps are becoming an increasingly popular alternative to conventional heating appliances because of their ability to heat and cool efficiently, resulting in low energy usage. For instance, an air-source heat pump, which transfers heat between the air outside your home and the air inside, can provide 1.5 to 3 times more heat energy to a home than the electrical energy it consumes. In addition, their energy and cost efficiency make them a desirable purchase for homeowners.

However, after purchasing your heat pump, are you facing some issues? While heat pumps are efficient and convenient, they are subject to wear and tear like any other machine.

If you’re wondering how to troubleshoot your heat pump, worry not. In this article, you will find helpful heat pump troubleshooting tips that will get your unit up and running in no time.

How to Fix Common Heat Pump Issues

  1. What Is a Heat Pump and How Does It Work?
  2. 10 Common Heat Pump Problems – Heat Pump Troubleshooting

What Is a Heat Pump and How Does It Work?

To learn how to troubleshoot a heat pump, it is important first to know the basics of its working.

All heat pumps work on the same basic principle. Rather than burning fuel to create heat, they simply move heat from one place to another.

There are two main types of heat pumps:

Air Source Heat Pumps

Air source heat pumps transfer heat between the air outside your home and the air inside.

They have further two types: ducted vs. ductless air-source heat pumps.

Ductless heat pumps are minimally invasive. Only a tiny hole in the wall is required to connect the indoor and outdoor units. Usually, there is one unit for each room. On the other hand, ducted heat pumps have one powerful central unit that heats or cools your entire home through ducts.

Shop Cielo Smart Products

Next-gen smart thermostat for HVAC systems. Achieve the perfect balance between comfort & savings.

Shop Now$12999$169

Award-winning smart AC controller for room air conditioners. Technology that goes above & beyond.

Shop Now$12999$159

Ultimate smart AC controller for mini-split, window & portable units. Powerful features, more control.

Shop Now$11499$149

Sleekest smart thermostat for mini-split, window & portable ACs. A design that magically blends.

Shop Now$7999$99

Smart AC controller that is engineered for affordable comfort. Small in size, big in benefits.

Shop Now$6999$99

Ground Source Heat Pumps

Ground source heat pumps transfer heat between the air inside your home and the ground outside.

Both air source and ground source heat pumps work on the same basic principle.

A heat pump absorbs heat energy from the outside air and transfers it to the inside air in heating mode. In cooling mode, a heat pump functions similarly to an air conditioner. It absorbs heat from the indoor unit and releases it through the outdoor unit.

10 Common Heat Pump Problems – Heat Pump Troubleshooting

With time, you might see a decrease in your heat pump’s efficiency or working. Diagnosing heat pump problems can be challenging since it could be due to plenty of reasons. Below you will find 10 of the most common problems and some residential heat pump troubleshooting tips.

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (8)

1.Heat Pump Running Constantly

Are you tired of sky-high energy bills and want to reduce your AC costs? If your heat pump is constantly running at full blast, it may be a significant factor behind high energy costs.

There are a few possible reasons why your heat pump is constantly running. Fortunately, most of them are easily fixable.

  • Incorrect Thermostat Settings

If you set your thermostat at a temperature that is either too high or too low, your heat pump would have to run constantly to maintain the set temperature.

Cielo Smart Thermostat

Equip your HVAC system with smart features and achieve the perfect balance between comfort & savings.

Shop Now

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (9)

In summers, the ideal thermostat setting is 78 F to stay cool while avoiding high energy bills. Set your thermostat to 78F for a few hours. Then, if you feel uncomfortable, decrease the temperature by a couple of degrees until you find the most comfortable temperature.

In winter, set your thermostat anywhere between 68 F to 72 F. If you are having trouble adjusting to this temperature, add extra layers of clothing. That’s not enough either? Set the temperature a few degrees higher and lower it to 72F gradually. If you are comfortable at 72F, try lowering the temperature a few degrees further.

Another reason could be that your thermostat is incorrectly calibrated. Here’s a handy guide on how to calibrate your thermostat.

  • Dirty Air Filters

For a heat pump to run efficiently, it needs a steady supply of fresh, clean air. If your heat pump’s air filters are dirty and clogged, less air will pass through, and as a result your heat pump will need to run constantly to maintain your set temperature.

Replacing or cleaning the air filters will solve this problem. On average, you should clean your air filters every two weeks and replace them every 3-4 months.

A visual inspection is more than enough to determine if your air filters are dirty. Hold them up against a light source, and if you can see through them unobstructed, you are good to go. If not, you can wash your air filters with soapy water and let them air dry before putting them back.

Read our detailed guide to clean an air conditioner.

  • Broken Compressor Contactor

A contactor is a small device that controls the flow of electricity to your heat pump’s components. If your compressor contactor breaks, your heat pump could run constantly. You’ll need a professional to diagnose whether you have a broken compressor contactor and if you need to replace it or not.

  • Dirty Coils

If you haven’t had your heat pump serviced for a while, there may be grime on the coils, which prevents it from working correctly. Also, since heat transfer occurs through the coils, they cannot function properly if dust, ice, or dirt are on them. Therefore, on average, you should clean your AC coils every two months.

  • Refrigerant Leak

A refrigerant leak also forces your heat pump to run constantly. A refrigerant is a liquid inside the coils through which heat transfer occurs between the indoor and outdoor air. If the refrigerant charge is low, adequate heat transfer cannot happen. As a result, your heat pump’s heating or cooling capacity decreases, so the heat pump must constantly run to maintain the temperature.

If you suspect a refrigerant leak, contact an HVAC professional to diagnose the leak and fix it. You should never attempt to recharge refrigerant or fix a refrigerant leak yourself.

  • Incorrectly Sized Heat Pump

If you have eliminated all other possibilities and your heat pump is still running constantly, it may be due to the wrong size. For example, if your heat pump is too small for your living space, it will have to run constantly to maintain the set temperature.

Check our air conditioner sizing guide to see whether your unit is compatible with your home’s needs.

2.Heat Pump Is Not Running

If you discover that your AC simply won’t turn on or has stopped running, there are a few easy heat pump troubleshooting steps you can follow. However, in some cases, you will have to contact a professional to diagnose the problem.

Here are some of the most common reasons your heat pump won’t turn on:

  • Thermostat Problems

A thermostat tells your heat pump what temperature to maintain. If the thermostat loses power for some reason, it cannot communicate to the heat pump what to do. As a result, your heat pump will not turn on.

If the thermostat’s display is not on, it indicates that it does not have power. Replace the batteries or, for hardwired units, check your home’s electrical panel. The circuit breaker may have tripped, or you may have a blown fuse. You can identify a blown fuse and replace it yourself. However, make sure that you disconnect the electrical power before removing a fuse.

Related:

  • Power Loss

Your heat pump’s indoor and outdoor units have separate power switches. First, check the power switch on or near the indoor unit and confirm it is set to ON. Next, check the power switch on or near the outdoor unit and see if it is set to ON. Finally, check your home’s electrical panel and see if you have a tripped circuit breaker or a blown fuse.

  • Closed Registers
Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (10)

If you have a ducted heat pump, check if all the registers are open and unobstructed. If you have obstructed the registers by any furniture or if they are clogged with dirt, it may feel as if your heat pump is not running because you are not receiving any air.

  • Dirty Air Filters

If your air filters are filthy and clogged, your unit is not receiving enough fresh air. As a result, your heat pump has to work overtime to maintain your desired temperature. The increased load can cause it to overheat and shut down.

Remove your air filters and hold them up against a light source. If you can see through them unobstructed, your air filters are clean. If not, wash your air filters with soapy water and let them air dry.

  • Faulty Starter Capacitor

The starter capacitor delivers power to the motor driving the heat pump. The capacitor provides a burst of energy to turn on the unit. If your starter capacitor breaks, your heat pump won’t turn on.

If you detect a faint clicking noise coming from your heat pump when you try and turn it on, that is a sign that your starter capacitor is faulty. You should never attempt to replace a starter capacitor on your own. Even with the power disconnected, it holds a lot of electric charge and can electrocute you.

  • Faulty Reversing Valve

The reversing valve allows your heat pump to cool and heat your home. If you have a faulty reversing valve, your heat pump may turn on in heating mode but not cooling mode and vice versa. If your heat pump only turns on for one of the modes, contact an HVAC professional to look at the reversing valve.

3.Outdoor Unit Is Frozen

In winters, a light layer of ice can cover your outdoor unit. Consequently, your heat pump has to go into defrost mode to remove that layer of ice. However, a thick layer of ice impedes heat transfer between the outside coil and outside air. As a result, your heat pump is unable to heat your house properly. If the ice is left on the external unit for too long, it could result in permanent damage to your heat pump.

Here are some reasons why this could be happening and some heat pump troubleshooting tip:

  • Outdoor Unit Is Blocked

If piles of snow have accumulated around your outside unit in winters, it can stop the ice on the outdoor unit from melting. Unfortunately, the reduced airflow can cause even more ice buildup—regularly clean snow from the area around the outside unit. To defrost the ice, never chip it away with a sharp tool. You can easily damage the coils. Instead, spray water from a hose to gradually melt the ice.

  • Outdoor Fan Problems

In your outdoor unit, the fan blows air over the coil with refrigerant in it, essential to the heat transfer process required for heating or cooling your house. If your outdoor fan is defective, there is little to no airflow. Lack of airflow can cause your outdoor unit to freeze over. Contact a professional to look at your outdoor fan motor in this case.

  • Low Refrigerant

Since refrigerant plays an important role in heat transfer, there can no longer be adequate heat transfer if there is a refrigerant leak. Eventually, your heat pump will not produce enough heat to melt the ice on the outside unit. If you suspect a refrigerant leak, never attempt to fix it yourself. Instead, always leave it to a professional.

  • Unit Is Not Defrosting

In winters, your heat pump periodically switches to air conditioning mode to defrost the ice on the outside unit. Air conditioning mode heats the outdoor unit so that any frost or ice melts. If the unit is not defrosting, ice can build up quickly.

The reversing valve is responsible for switching the heat pump from heat mode to air conditioning mode. If the reversing valve breaks, the unit does not defrost. You should contact a seasoned HVAC professional to take a look at the reversing valve.

Your unit could also have a malfunctioning defrost timer. The defrost mode on your heat pump is designed to turn on periodically. If your defrost timer is defective, your unit is not defrosting as frequently as it should, resulting in ice buildup. An HVAC professional can determine whether your defrost timer is working correctly.

  • Clogged Filters

Dirty air filters impede airflow. If there isn’t enough air circulating the coils, the coils become too cold and freeze over. Once the coils freeze over, they cannot heat or cool properly, causing a layer of ice to build upon the outside unit.

  • Dirty Coils

If you have filthy coils with grease or grime on them, effective heat transfer between the coils and the outside air cannot occur. When the coils cannot lose heat to the air, the refrigerant inside them becomes too cold, leading to a layer of ice forming on the coils. As a result, your heat pump can neither heat nor cool properly. It also leads to it not being able to defrost the outside unit efficiently. Thus, the icing upon the external unit worsens.

  • Water on Outdoor Unit

If water is constantly dripping on your outdoor unit in winters, it can freeze and form a layer of ice. First, defrost the outside unit by either turning on the defrost mode or spraying water from a hose. Then locate the source of the water, such as a leaking gutter, and fix it.

4. Indoor Air Handler Not Working

An air handler works in conjunction with your heat pump to distribute air inside your home. If your outdoor unit is running, but you don’t feel any air coming from the registers, your indoor air handler may not be running.

Some reasons your indoor air handler is not activating include:

  • Tripped Circuit Breaker

Your indoor and outdoor units have separate electrical connections. Check the circuit breaker for your indoor unit and see if it has tripped. Also, keep an eye out for any blown fuses.

If your air conditioner’s circuit breaker keeps tripping, then check this article for ten possible causes!

  • Bad Wiring Connection

You could also have loose or frayed wires that are preventing power from reaching the indoor air handler.

  • Blown Blower Motor

The worst-case scenario is that you have a blown blower motor. The blower motor is responsible for circulating air throughout your house. A blown blower motor means that the heat pump cannot distribute air throughout your home. Unfortunately, you cannot replace a blown blower motor on your own. Instead, you must contact an HVAC professional to do the job for you.

5.Heat Pump Not Heating

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (11)

Most people expect their homes to be cozy in winters. That’s likely why you installed a heat pump in the first place. So, it can be uncomfortable, to say the least, if your heat pump stops heating.

Here are some reasons your heat pump is not heating and what you can do to fix it:

  • Incorrect Thermostat Settings

Double-check if you’ve set your thermostat to cooling mode. If that is not the case, check if your fan is running continuously. If your fan is running continuously, the system is not actively heating. After that, set the system to heat mode and the fan to auto.

  • Incorrectly Calibrated Thermostat

Your thermostat could simply be reading the wrong temperature, leading to issues with heating. Have a look at your thermostat’s manual to see if there are any instructions on recalibrating it. Check your thermostat manual for thermostat calibration guidelines. If the issue isn’t fixed, you can have it replaced or recalibrated by a professional.

  • Dirty Air Filters

If your air filters haven’t been cleaned or replaced for a long time, dirt or debris could have clogged them. If your air filters are clogged, your unit does not receive adequate airflow. As a result, it stops heating. Simple wash your filters with soapy water or replace them to fix this problem.

  • Low Refrigerant

If there is a refrigerant leak, adequate heat transfer cannot happen, and your heat pump cannot warm your home.

  • Outside Unit Is Blocked

Since your heat pump operates through heat transfer, it cannot pull air from the outside to heat your home if snow or debris has blocked the outside unit. Go outside and clean any debris around your outdoor unit.

  • Leaking Ducts

For a central heat pump, if you have sky-high energy bills but less usage to justify it, you could have a duct leak. You can check any exposed ductwork for leaks by holding your hand over connection points. Unfortunately, most of your ductwork is hidden, so you will have to contact an HVAC professional to diagnose any leak deep inside.

6.Heat Pump Not Cooling

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (12)

Has your heat pump failed in the middle of a heatwave? Don’t panic! Instead, read these possible reasons why your heat pump is not cooling, along with what to do.

  • Thermostat Problems

Ensure you’ve set your thermostat to cool mode. If the settings are fine, you could have an incorrectly calibrated thermostat. You can take some troubleshooting steps to find out what is wrong with your thermostat.

  • Faulty Reversing Valve

If your heat pump works in heating mode but not cooling mode, you could have a faulty reversing valve. Unfortunately, the reversing valve can only be repaired or replaced by a professional.

  • Low Refrigerant

If your refrigerant levels are too low, your heat pump won’t cool or heat effectively. Contact a professional to detect any leak and fix it. Be mindful that your HVAC technician does not just top up the refrigerant without fixing the leak.

  • Dirty Air Filters

Dirty air filters block airflow to your heat pump. As a result, your heat pump cannot draw enough air from the inside to cool effectively. Regularly clean and replace your air filters.

  • Outdoor Unit Is Blocked

If your outdoor unit is covered in debris or blocked by branches or foliage, it cannot effectively expel hot air outside. As a result, its cooling ability decreases. Regularly clean the area around your outdoor unit to prevent blockage.

  • Dirty Coils

If your coils are dirty, heat transfer between the refrigerant in the coils and the air cannot occur. Check if there is any dirt or frost on your coils. After that, clean your heat pump coils. If you see any ice buildup on your coils, allow it to melt. Never try to physically remove the ice, as you can damage the delicate coil fins.

  • Incorrectly Sized Unit

If your heat pump is too small, it won’t be able to cool your entire house effectively. A certified HVAC technician can carry out a sizing assessment to determine whether your heat pump is the correct size or not.

7.Heat Pump Doesn’t Switch from Heat to Cool or Vice Versa

If you’re having trouble switching from heat mode to cool mode and vice versa, then there might be an issue with the reversing valve.

  • Faulty Reverse Valve

The reversing valve is responsible for switching the heat pump from one mode to the other. It reverses the refrigerant flow and allows your heat pump to both heat and cool your home. If your heat pump does not switch from one mode to the other or works fine in one mode but not the other, there is a problem with the reversing valve.

Contact an HVAC professional to inspect your reversing valve and fix any issues.

8.Heat Pump Is Short Cycling

Short cycling is when your heat pump repeatedly turns off soon after it turns on. Short cycling has several causes:

  • Improperly Sized Unit

If your unit is too large for your home, it will cool or heat your home too quickly. Once it achieves the desired temperature, it will shut down. Contact an HVAC technician to perform load calculations to check whether your heat pump is an appropriate size for your house.

  • Overheating System

If you have dirty air filters, it can restrict airflow and cause your system to overheat. So as a defensive mechanism, your heat pump shuts down.

  • Refrigerant Leaks

If there is a refrigerant leak, your heat pump may not have enough refrigerant to complete an entire cycle. Only an HVAC professional can diagnose and fix a refrigerant leak.

  • Incorrectly Calibrated Thermostat

If your thermostat generates an incorrect reading, your heat pump will have to keep turning on and off to achieve the desired temperature. First, ensure your thermostat is correctly calibrated. If not, you can try to recalibrate it or replace it.

Apart from incorrect calibration, you might have placed your thermostat in the wrong area.

For example, if you have put it in direct sunlight, it will detect a higher temperature. Resultantly, telling your heat pump to shut down early even though it has not achieved the desired temperature. Similarly, if you place your thermostat near the ducts, the temperature it detects does not indicate the actual temperature inside your house.

9.Unit Is Leaking Liquid

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (13)

If you notice mold growing on the walls near your heat pump, there may be a leak. Never ignore a heat pump leaking liquid. Apart from causing decay, stagnant water inside your heat pump can also cause electrical damage.

Here are some of the main reasons your unit could be leaking liquid:

  • Refrigerant Leak

If you have a refrigerant leak, ice can build up on the evaporator coils, which can hamper the efficiency of your heat pump. In addition, when you turn off your heat pump, this ice melts, causing your heat pump to leak water.

  • Drain Line Is Clogged

When your heat pump is on cooling mode, it draws in humid air from your home to cool. This process results in condensation. The condensate travels to the condensate pan and is then drained through the drain line. If your condensate pan has any cracks, water can leak through it. Similarly, if your drain line is clogged, it can also lead to water overflowing. If you suspect your drain line is clogged, you can unclog it yourself or contact a professional.

10.Weird Smells

Your sense of smell is one of the best tools to check if there is anything wrong and if you require heat pump troubleshooting.

Here are some of the main reasons your heat pump smells suspicious:

  • Mold Growth

If you smell a musty odor, chances are there is mold growing inside your heat pump or on the surrounding walls. Mold in air ducts can also have adverse effects on your health so if you suspect mold, turn off the heat pump so no mold spores can circulate inside your home. You can clean the mold yourself if the extent of the problem is not too severe. If there is significant mold, you will either need to contact a professional for deep cleaning or replace the unit.

  • Animal Infiltration

If your heat pump smells like it is rotting, an animal may have crawled in and died. Firstly, take off the cover. See if you can remove the carcass yourself. If you are having difficulty, you can always contact an HVAC professional to do it for you.

  • Electrical Issues

If your heat pump smells like it is burning, there may be some severe electrical issue on the inside, such as a damaged wire or failing motor. Never dismiss a burning smell. Turn off the circuit breaker immediately and contact an HVAC professional to find the cause of the smell.

A heat pump is a versatile appliance with numerous advantages. However, like all electrical appliances, it is prone to occasional problems. With these handy heat pump troubleshooting tips, you are sure to be prepared whenever you run into any issues with your unit.

Share:

I'm definitely into heat pumps! I've delved into their mechanics and operation, so let's break it down. Heat pumps work on the principle of transferring heat rather than generating it by burning fuel. They have two main types: air source and ground source heat pumps. The air source variant transfers heat between the outdoor and indoor air, while the ground source type moves heat between the indoor air and the ground.

For troubleshooting, several common issues might arise:

  1. Constant Running: Often due to incorrect thermostat settings, dirty air filters, or a faulty compressor contactor.
  2. Unit Not Running: This could stem from thermostat issues, power loss, closed registers, or a faulty starter capacitor.
  3. Outdoor Unit Freezing: Accumulation of snow or ice, outdoor fan problems, low refrigerant, or a malfunctioning defrost cycle could cause this.
  4. Indoor Air Handler Problems: Potential causes include tripped circuit breakers, bad wiring connections, or a blown blower motor.
  5. Not Heating: Issues might arise from incorrect thermostat settings, dirty air filters, low refrigerant, or blockages around the outdoor unit.
  6. Not Cooling: Similar culprits like thermostat settings, a faulty reversing valve, low refrigerant, dirty filters, or blockages around the outdoor unit can hinder cooling.
  7. Difficulty Switching Modes: This might indicate a problem with the reversing valve.
  8. Short Cycling: Oversized units, overheating systems, refrigerant leaks, or improperly calibrated thermostats could be the cause.
  9. Leaking Liquid: Leaks might be from a refrigerant leak or a clogged drain line.
  10. Unusual Smells: These could stem from mold growth, animal infiltration, or electrical issues.

Knowing these issues and their potential causes helps when troubleshooting a heat pump. It's a complex system, but understanding its operation and these possible hiccups makes problem-solving much more manageable.

Heat Pump Troubleshooting: 10 Common Heat Pump Issues and Their Fixes (2024)

References

Top Articles
Latest Posts
Article information

Author: Gov. Deandrea McKenzie

Last Updated:

Views: 6301

Rating: 4.6 / 5 (66 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Gov. Deandrea McKenzie

Birthday: 2001-01-17

Address: Suite 769 2454 Marsha Coves, Debbieton, MS 95002

Phone: +813077629322

Job: Real-Estate Executive

Hobby: Archery, Metal detecting, Kitesurfing, Genealogy, Kitesurfing, Calligraphy, Roller skating

Introduction: My name is Gov. Deandrea McKenzie, I am a spotless, clean, glamorous, sparkling, adventurous, nice, brainy person who loves writing and wants to share my knowledge and understanding with you.